Record and log relative humidity,
temperature & CO2 readings and graph data on your PC
Features & Applications:
Poor air quality cannot only affect ambient air, but result in
decay or damage to a structure. Equipped with infrared technology
to accurately measure these components. Measure RH, temperature
and CO2 with precision-enabling you to assess the conditions
in the test area.
Designed for residential and commercial applications, it also has
the ability to calculate and display cfm/person ventilation rate-hence
identifying ventilation-related problems such as moisture build-up,
combustion gas build-up, etc. Record your findings on your computer
utilizing the included graphical software and cable.
Features:
- Dual beam absorption infrared
- Display: LCD
- Sample method: diffusion or flow through (50 – 100 ml/min)
- Power supply: 4 AA batteries (not included) or 6V DC from external
AC/DC adapter (included)
- Includes graphing software & computer cable
Applications:
Spec Summary:
| Temperature (internal sensor) |
|
Range: |
-4 to +158°F (-20 to +70°C)
Range for internal sensor when used outside of case:
-40 to +248°F (-40 to +120°C) |
Accuracy: |
±1.27°F (±0.7°C) at +70°F |
Resolution: |
0.7°F (0.4°C) at +70°F |
Response
time still in air: |
15 min. typical with sensor inside
case;
1 min. typical with sensor outside case |
| Relative humidity (user-replaceable
RH sensor) |
|
Range: |
25 to 95% RH at +80°F for intervals of > 10
seconds,
non-condensing and non-fogging |
Accuracy: |
±5% |
Response time: |
10 min. typical in air |
Sensor operating environment: |
+41 to +122°F (+5 to +50°C)
non-condensing and non-fogging |
| Power: |
|
|
External input accepts the following sensors:
Wide range of temp sensors (TMCx-Hx series)
Split-core CTs for AC current (5 Models)
4-20 mA input cable (CABLE-4-20mA)
0-2.5 V DC input cable (Cable-2.5-Stereo) |
Input range: |
0 to +2.5 Volts DC |
Resolution: |
10 mV (8-bit) |
|
External 2.5 Volt input
2.5 mm jack: external input ground, input, switched 2.5
Volt
output; external input ground connection is not the same
as PC interface connection ground and should not be
connected to any external ground |
Accuracy: |
±10 mV ±1% of reading |
Out power: |
+2.5 Volts DC at 2 mA, active only during measurements |
| Performance |
|
|
CO2 Channel |
Measurement Range: |
0-4,000 PPM voltage output
0-10,000 PPM display |
Resolution: |
±1 ppm |
Accuracy: |
±50 ppm or ±5% of reading (up to 1.5% or 15,000
ppm),
whichever is greater |
Warm-Up Time: |
<60 seconds at 72°F |
Operating Conditions: |
32-122°F
0-95% RH, non-condensing |
Storage Temperatures: |
-40 to 140°F |
Calibration Interval: |
12 months, offset adjustment using single gas
at 0-1000 ppm CO2. |
|