Easily locate the presence of combustion fumes with the Telaire Handheld Indoor Air Quality Monitor!
Features & Applications:
Equipped with Telaire's patented dual beam Absorption Infrared technology, the easy-to-use Telaire Handheld Indoor Air Quality Monitor is designed for use in residential or commercial applications. The 7001 has the ability to display CO2 readings and calculate outside air ventilation rates in cfm/person. It is the ideal tool for identifying energy saving opportunities in over-ventilated spaces, determining if air quality complaints are due to insufficient ventilation, or locating the presence of combustion fumes generated from vehicles and appliances. A power adapter is included.
Features:
- Patented dual beam, Absorption Infrared gas sensor ensures long term stability and durability.
- Large, easy to read display. Temperature displayed in °F or °C. CO2 displayed in ppm. Easily adjusted for altitude changes.
- Fast, simple calibration using external port and display. Calibrate with ambient air or bottled gas.
- Calibrate, set elevation, change °F or °C using on-board controls or optional computer interface (UIP Kit model 2072)
- Flip out stand for desktop monitoring.
- Voltage output via RJ45 connector provides easy interface to most dataloggers.
- Plug-In AC power adaptor.
- Operates for up to 80 hours on 4 AA alkaline batteries (not included).
- Displays cfm-per-person ventilation rate based on CO2 inside outside differential reading.
Applications:
- Identify areas with low or substandard ventilation
- Identify hidden energy savings in over-ventilated spaces.
- Determine if ventilation is a factor in air quality complaints.
- Locate the presence of combustion fumes
- Use as a reference to calibrate wall mounted CO2 sensors
Spec Summary:
| Method: |
Dual Beam Absorption Infrared |
| Sample Method: |
Diffusion or flow through (50 to 100 ml/min) |
| Display-LCD: |
Independent CO2 and temperature readings. Calculates and displays ventilation rates. |
| General: |
| Operating Conditions: |
32°F to 122°F (0°C to 50°C)
0 to 95% RH, non-condensing |
| Storage Temperatures: |
-4°F to 140°F (-20°C tp 60°C) |
| Certification: |
FCC Class 15 Part B |
| Warranty: |
18 months parts and labor |
| Performance-CO2 Channel: |
| Measurement Range: |
0 to 10,000 ppm display
0 to 4000 ppm voltage output |
| Display Resolution: |
±1 ppm |
| Accuracy: |
±50 ppm or 5% of reading, whichever is greater |
| Repeatability: |
±20 ppm |
Temperature Dependence:
|
±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced at 25°C. |
| Pressure Dependence: |
0.13% of reading per mmHg (corrected via user input for
elevation) |
| Response Time: |
<60 seconds for 90% of step change |
| Warm-Up Time: |
<60 seconds at 72°F (22°C) |
| Calibration Interval: |
12 months, offset adjustment using single gas at 0 to 1000 ppm CO2. Full factory calibration available. |
| Performance-Temperature Channel: |
| Temperature Range: |
Voltage output: 32°F to 104°F (0°C to 40°C)
Display: 32°F to 122°F (0°C to 50°C) |
| Display Resolution: |
0.1°F (0.1°C) |
| Display Options: |
°F, °C, of off. Set with panel button. |
| Accuracy: |
±2°F (±1°C) |
| Response Time: |
20 to 30 minutes (case must equilibrate with
environment) |
| Calibration Interval: |
12 months, offset adjustment using temperature standard at 50°F to 86°F (10°C to 30°C). Full factory calibration available. |
| Output-Analog: |
| CO2: |
0 to 4 VDC, 1 mV/ppm (4000 ppm maximum) |
| Temperature: |
0 to 4 VDC linear, 32°F to 104°F (0°C to 40°C) |
| Output Impedance: |
100 ohms |
| Digital Output: |
RS232 for use with Telaire CO2View graphing software |
| Wiring Connection: |
One RJ45 to connector dual analog output plus digital
output |
| Power Supply: |
| Battery Type: |
Four AA batteries (not included) |
| Battery Operation: |
80 hours (alkaline) |
| External: |
6 VDC from external AC/DC adapter (included) |
| Power Requirements: |
100 mA peak, 20 mA average from 6V |
|